Skip to content
CALL TODAY phone number 561.229.1418
CALL TODAY phone number 561.229.1418

PSI Arizona B-3 (CR-61) Limited Remodeling and Repair Contractor (residential/commercial) Certification Package

Save 9%
Original price $1,801.15
Current price $1,637.41

To be certified The Arizona Business Management exam must be taken as well.

SCOPE OF WORK
Remodeling and repairs to existing structures or appurtenances, excluding swimming pools or spas, not to exceed $25,000 per project per dwelling. Work on electrical, plumbing, air conditioning systems, or boilers that require a building permit must be subcontracted to an appropriately licensed contractor. The scope of work allowed under the CR-7R carpentry classification is included. Doors, Gates, Windows, and Accessories, Removable Formwork and shoring, Nailing and Stapling.

All rough and finish general carpentry work on new and existing structures, including installation of related hardware and accessories, without dollar limitation. All general remodeling, additions, replacements, and repairs to existing structures, and pre-manufactured items on existing structures, except electrical, plumbing, and air conditioning system work which shall be sublet to properly licensed contractors. A single contract for remodeling, repair or a combination of both, shall not exceed $50,000.

Remodeling or repair of an existing residential structure or appurtenance except for electrical, plumbing, mechanical, boilers, swimming pools, or spas which must be subcontracted to an appropriately licensed contractor. The scope of work allowed under the C-7 carpentry classification is included within this scope. Doors, Gates, Windows, and Accessories, Removable Formwork and shoring, Nailing and Stapling. The trade test is considered equivalent for these classifications and upon passing the CBME and trade exam, any of these license classification may be applied for without further testing.

the exam is 75 questions taken over 180 minutes. The minimum required score to pass is a 70%.

The reference material listed above was used to prepare the questions for this examination. The examination may also contain questions based on trade knowledge or general industry practices. Except for Code books, you can base your answers on later editions of references as they become available. For Code questions, the examinations will be based only on the edition of the Code book that is listed. 

Candidates may use a silent, nonprinting, non-programmable calculator in the examination center.

The first 3 books may be brought into the exam center, the last 9 may not.

The following reference material is allowed in the examination center:

Code of Federal Regulations - 29 CFR Part 1926 (OSHA)

International Residential Code for One- and Two-Family Dwellings, 2009

International Building Code, 2009,

The following reference material is not allowed in the examination center

Pipe and Excavation Contracting

Carpentry and Building Construction, 2010

Contractors Guide to Quality Concrete Construction, 3rd Edition, 2005

Modern Masonry - Brick, Block, Stone

Roofing Construction & Estimating

Walker's Insulation Techniques and Estimating Handbook

PDCA Craftsman's Manual and Textbook, Eighth Edition,

Standard Practice for Installation of Rigid Poly Vinyl Chloride

Gypsum Construction Handbook, 7th edition, 2014

Candidates are responsible for bringing their own references to the examination center. Reference materials may be highlighted, underlined, annotated and/or indexed prior to the examination session. However, references may not be written in during the examination session. Any candidate caught writing, highlighting, underlining and/or indexing in the references during the examination will be reported to the Arizona Registrar of Contractors. Furthermore, candidates are not permitted to bring in any additional papers (loose or attached) with their approved references. References may be tabbed/indexed with permanent tabs only. (permanent tabs are defined as tabs that would tear the page if removed). Temporary tabs, (defined as Post-It notes, or other tabs that may be removed without tearing the page) are not allowed and must be removed from the reference before the exam will begin. If you are downloading from the Internet, you may bring this reference into the testing center with you as long as it is bound. You can have it spiral bound or you may hole-punch it and put it in a binder. 

|title=Mandatory Business Exam|psi-arizona-buisness-management-exam-certification-package|title=Reference Materials|osha-construction-standards-regulations-29-cfr-1926|2009-international-building-code|2009-international-residential-code-for-one-and-two-family-dwellings|pipe-excavation-contracting|carpentry-building-construction-2010|the-contractors-guide-to-quality-concrete-construction-third-edition|modern-masonry-brick-block-stone-8th-edition|roofing-construction-estimating-paperback|walkers-insulation-techniques-and-estimates-handbook-1|pdca-craftsman-manual-and-textbook-8th-ed|standard-practice-for-installation-of-rigid-poly-vinyl-chloride-pvc-siding-and-soffit|the-gypsum-construction-handbook-7th-edition|title=Application Service|application-service|
Uptryve Systems Uptryve Systems